Designed for Data Center, the ebm-papst R3G560-8317080795 is a 380-480V EC backward-curved centrifugal fan, identified by a listed airflow of 17,350 m³/h. This assists electrical and mechanical review.
| Rated Voltage(V) | 3`380-480 |
|---|---|
| Size(mm) | 560 |
| Max.Air Flow(m³/h) | 17350 |
| Max.Pressure(Pa) | 920 |
| Input Power(W) | 3350 |
| Speed(rpm) | 1780 |
| Noise(db) | 96 |
R3G560-8317080795 is an ebm-papst EC centrifugal fan for Data Center Cooling, where controlled heat removal and airflow management must match the actual duty point. Its model-specific format supports OEM builds, retrofit planning and replacement sourcing.
Documented selection points include 3`380-480 V supply, 3350 W input, 560 mm size, up to 17350 m3/h airflow. These values support electrical, envelope and duty-point comparison.
For procurement, verify voltage, duty point, dimensions, connector and mounting. Correct sizing and clear airflow paths support stable operation, controlled noise and long service life. Confirm speed control, IP protection and approvals in the exact-model datasheet.
The ebm-papst R3G560-8317080795 from the RadiPac EC Centrifugal series is a direct energy-saving replacement for legacy AC fans including R4D, R2D. Key benefits:
R3G EC fans operate at V with W rated power. When replacing AC models, wire the 0-10V control signal alongside the standard three-phase power cable.
How the R3G560-8317080795 compares to nearby R3G series variants:
| Model | R3G630-PC08-03 | R3G190-RC05-03 | R3G220-RC05-03 | R3G220-RC09-08 |
|---|---|---|---|---|
| Air Flow | 12470 m³/h | 735 m³/h | — | — |
| Power | 4250 W | 83 W | 85 W | 51 W |
| Noise | 74 dB | — dB | — dB | — dB |
| Size | 630 mm | 190 mm | 220 mm | 220 mm |
All R3G series fans from Hengrui include performance curves, mounting instructions and factory warranty. Contact us for project-specific selection.
Data Center CRAH/CRAC Units: The R3G560-8317080795 delivers reliable cooling for Computer Room Air Handling with 24/7 uptime. EC motor enables precise temperature control.
AHU Air Handling: Engineered for integration into Air Handling Units.
Industrial Process Ventilation: Machinery cooling, enclosure ventilation and process air movement. Hengrui provides custom engineering support.
Correct sizing and operation within documented limits can reduce avoidable thermal stress and maintenance events; project savings require duty-cycle analysis.
The workbook marks it In Stock, but quantity and lead time should be reconfirmed at quotation because availability can change.
The supplied comparison identifies a listed airflow of 17,350 m³/h; review it together with the other listed ratings rather than as a standalone selection criterion.
Match required airflow and pressure on the exact performance curve, then verify voltage, power, dimensions and environmental limits.

For Cleanroom, R3G400-8317084403 provides an EC backward-curved centrifugal fan format with 400 mm dimensions for installation planning. Rated voltage is not shown in the supplied table and must be checked before selection.
Read More
Intended for Cleanroom, the R3G400-8317080005 is an EC backward-curved centrifugal fan characterized by 400 mm dimensions for installation planning. Its rated voltage is absent from the supplied data and requires confirmation.
Read More
R3G400-8317080492 targets Cleanroom in an EC backward-curved centrifugal fan configuration. The available data highlights 400 mm dimensions for installation planning, but does not provide a rated-voltage value.
Read More
Designed for Air Purification, the ebm-papst R3G225-8317084118 is a 200-277V EC backward-curved centrifugal fan, defined by 225 mm dimensions for installation planning. The data helps compare K-series variants.
Read More
In Cleanroom equipment, R3G280-8317084540 is an EC backward-curved centrifugal fan whose documented profile includes 280 mm dimensions for installation planning; the supplied table leaves the rated voltage unspecified.
Read More
The R3G310-8317083844 serves Cleanroom as an EC backward-curved centrifugal fan, with 310 mm dimensions for installation planning as its clearest supplied attribute. No rated voltage is listed in the provided table.
Read More