Get Quote
Home > Products > By type > Compact Fans > RL90-18/56 | ebm-papst DC Compact Centrifugal Fan for Air Handling Units & Fan Arrays

RL90-18/56 ebm-papst Compact Fan

Brand :
ebmpapst
Model:
RL90-18/56 | ebm-papst DC Compact Centrifugal Fan for Air Handling Units & Fan Arrays
Type:
Compact Fans
Industry:
HVAC & Ventilation
Description:

RL90-18/56 is a 230 VAC compact axial fan for electronic equipment, heat pumps, equipment cooling. Its main supplied feature is a 121*121*37 mm size specified in the upload data. It also lists 39.95 m³/h maximum airflow stated for this model. Review pressure requirement for commissioning review.

Product Features

Rated Voltage(V)230
Size(mm)121*121*37
Max.Air Flow(m³/h)39.95
Input Power(W)20
Speed(rpm)2450
Noise(db)60

Product Features

Compact Cooling

Installation makers serving air-handling, HVAC and refrigeration installation can integrate ebm-papst RL90-18/56 as a DC centrifugal fan for directed ventilation and internal element-level generated heat removal.

The tightly packaged format targets local forced-air thermal management where installation space, control-circuit consumption, sound and service reliability must be balanced.

The listed air delivery of 39.95 m3/h remains subject to the resistance and recirculation of the finished installation.

This helps engineering teams translate air delivery into lower internal element temperature, steadier service and a more repeatable installation system engineering. Confirm the exact operating point before production release. Preserve the specified air delivery direction during assembly.

Application Industry

Frequently Asked Questions

Does RL90-18/56 require a separate controller?

The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.

Can RL90-18/56 be considered for continuous operation?

The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.

What should be checked before installing RL90-18/56?

Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.

Can RL90-18/56 help reduce operating cost?

No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.

Which certifications are documented for RL90-18/56?

The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.

What rated voltage is listed for RL90-18/56?

The upload row lists 230 VAC. Confirm phase, frequency, terminals, and local supply conditions before wiring.