Intended for Data Center Cooling, ebm-papst S6E630-AN01-01 is a 230 V AC axial fan, offering a documented speed of 860 rpm. This enables specification-led selection. Its documented data supports integration planning.
| Rated Voltage(V) | 230 |
|---|---|
| Size(mm) | 630 |
| Max.Air Flow(m³/h) | 6705 |
| Max.Pressure(Pa) | 100 |
| Input Power(W) | 600 |
| Speed(rpm) | 860 |
The ebm-papst S6E630-AN01-01 is an AC axial fan for data center cooling, providing directed airflow in enclosures and cooling assemblies.
Data includes 230 V operation, airflow up to 6705 m³/h and pressure up to 100 Pa for matching airflow to system resistance. The datasheet lists ball-bearing support, IP54 protection for durable motor support. Installed noise depends on the duty point and airflow path. Correct electrical selection and clear inlet spacing support efficient cooling, reliable operation and long fan life.
Suitable for OEM engineers, manufacturers and maintenance buyers, the S6E630-AN01-01 should be checked for wiring, mounting, duty point and ambient limits before selection. Its documented operating data supports model comparison, replacement planning and purchasing review.
Provide service access, keep the airflow path clean, inspect wiring and mounting, and investigate abnormal noise or vibration before continued use.
Correct sizing and operation within documented limits can reduce avoidable thermal stress and maintenance events; project savings require duty-cycle analysis.
Its documented 230 V AC axial fan configuration provides a traceable match for projects whose electrical and airflow requirements align with the model data.
Control capability and input method must be confirmed in the exact-model datasheet and wiring diagram; do not infer them from the fan family alone.

Aimed at Refrigeration Cooling, ebm-papst S4D350-AN08-50 is a 400 V AC axial fan, distinguished by a listed acoustic value of 58 dB. It provides a practical sizing reference. Its documented data supports integration planning.
Read More
Built for Refrigeration Cooling, the ebm-papst S4D450-CO14-01/F01 is a 400 V AC axial fan, offering 450 mm dimensions for installation planning. This enables specification-led selection.
Read More
Developed for Refrigeration Cooling, ebm-papst S4D400-AP12-03/A01 is a 400 V AC axial fan, with a documented speed of 1,690 rpm. The rating clarifies its operating profile. Its documented data supports integration planning.
Read More
Configured for Refrigeration Cooling, ebm-papst S4D500-AK14-06 is a 400 V AC axial fan, centered on a listed acoustic value of 74 dB. The data helps compare K-series variants. Its documented data supports integration planning.
Read More
Aimed at Refrigeration Cooling, ebm-papst S4D400-AP12-03 is a 400 V AC axial fan, documented with a documented speed of 1,690 rpm. This supports duty-point selection. Its documented data supports integration planning.
Read More
Specified for Refrigeration Cooling, ebm-papst S4D300-AS34-37 is a 400 V AC axial fan, defined by a documented 90 W input rating. This helps guide installation planning. Its documented data supports integration planning.
Read More