Get Quote
Home > Products > By type > Axial Fans > 3615KL-05W-B50-PR1 | NMB 24VDC 7.68W DC Axial Fan for servers and data communications equipment

3615KL-05W-B50-PR1 NMB Axial Fan

Brand :
NMB
Model:
3615KL-05W-B50-PR1 | NMB 24VDC 7.68W DC Axial Fan for servers and data communications equipment
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

3615KL-05W-B50-PR1 is a 24 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 35 dB noise data recorded for this model. It also lists a 90*90*38 mm size specified in the upload data. Review controller compatibility for retrofit assessment.

Product Features

Rated Voltage(V)24
Size(mm)90*90*38
Max.Air Flow(m³/h)23.65
Input Power(W)7.68
Speed(rpm)4000
Noise(db)35

Product Features

Compact DC Airflow

The NMB 3615KL-05W-B50-PR1 reinforces data centers and communication hardware as a DC axial fan, combining a constrained-space heat removal role with a clear mechanical and electrical integration path.

A documented hardware-level test links the selected fan to measurable heat removal value instead of isolated catalogue figures.

A coordinated impeller, frame and motor path helps convert electrical input into useful heat removal moving air without unnecessary flow disturbance.

The listed moving air of 23.65 m3/h remains subject to the resistance and recirculation of the integrated installation. Preserve the specified moving air direction during assembly. Review the approved electrical interface for the complete suffix. Validate sound and temperature in the finished enclosure.

Application Industry

Frequently Asked Questions

How should I select between 3615KL-05W-B50-PR1 and a nearby model?

Compare the full model suffix, voltage, size, motor or controller type, mounting, airflow, pressure, power, speed, and protection; do not copy data from a similar model.

What equipment is 3615KL-05W-B50-PR1 suited to?

The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.

How do I confirm 3615KL-05W-B50-PR1 is compatible with my equipment?

Match the complete model code, voltage, dimensions, mounting arrangement, airflow direction, performance point, and control interface to the equipment.

Which certifications are documented for 3615KL-05W-B50-PR1?

The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.

What mounting details matter for 3615KL-05W-B50-PR1?

Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.

What should I check if 3615KL-05W-B50-PR1 develops a cooling fault?

Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.

Message Form