4715MS-23T-B50 is a 230 VAC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 120*120*38 mm size specified in the upload data. Review mounting envelope for final model confirmation.
| Rated Voltage(V) | 230 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 173.4 |
| Max.Pressure(Pa) | 70.5 |
| Input Power(W) | 14 |
| Speed(rpm) | 2900 |
| Noise(db) | 41 |
The NMB 4715MS-23T-B50 contributes to data centers and communication assembly as an AC axial fan, combining a constrained-space forced-air cooling role with a clear mechanical and electrical integration path.
Completed approval should consider mounting, connector or lead arrangement, moving air direction and access for future service.
A coordinated impeller, frame and motor path helps convert electrical input into useful forced-air cooling moving air without unnecessary flow disturbance.
Listed moving air of 173.4 m3/h and pressure of 70.5 Pa provide starting points for duty-point evaluation in the completed assembly. Preserve the specified moving air direction during assembly. Review the approved electrical interface for the complete suffix.
When fitted in servers and data-communication hardware, 4715MS-23T-B50 cools computing and network assemblies within the available machinery space. The result supports robust operation while keeping the temperature management function understandable for future service work.
When integrated in power supplies, inverters and control cabinets, 4715MS-23T-B50 cools power modules and controls within the available application space. This gives application makers a practical cooling element that reinforces application reliability without changing the stated industry direction.
NMB supplies model 4715MS-23T-B50 for industrial automation hardware, where directed ventilation flow ventilates drives and production electronics. Forced-air cooling contributes to hardware availability during long duty cycles and repeated load changes.
As part of medical and laboratory instruments, NMB 4715MS-23T-B50 performs a defined forced-air cooling task and cools enclosed instrument electronics. The application values controlled ventilation because internal space and acoustic limits constrain forced-air cooling choices.
It may be evaluated for high-reliability cooling using the supplied parameters, but duty cycle, redundancy, ambient limits, and protection must be confirmed at system level.
Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.
The upload sheet marks the item as In Stock, but available quantity should be confirmed when the order is placed.
Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.
Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.