DKHR450-4KW.138.5HA is a 400 VAC centrifugal fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 590 Pa maximum pressure stated for this model. It also lists a 450 mm size specified in the upload data. Review controller compatibility for cooling validation.
| Rated Voltage(V) | 400 |
|---|---|
| Size(mm) | 450 |
| Max.Pressure(Pa) | 590 |
| Input Power(W) | 910 |
| Speed(rpm) | 1300 |
Designed around the thermal management needs of air-handling, HVAC and refrigeration equipment, the Rosenberg DKHR450-4KW.138.5HA provides a centrifugal fan format for OEM equipment integration.
The listed 400 V supply and 910 W input give electromechanical designers a defined basis for power and interface planning.
The centrifugal air delivery path is intended for systems that must overcome resistance rather than relying only on unrestricted volume flow.
Prototype testing can confirm the fitted air delivery path and prevent free-air data from being mistaken for in-unit performance. Preserve the specified air delivery direction during assembly. Review the approved electromechanical interface for the complete suffix. Validate sound and working temperature in the finished chassis.
Applied to HVAC and ventilation systems, Rosenberg model DKHR450-4KW.138.5HA provides supply or exhaust working temperature management flow. Unit resistance can shift delivered working temperature management flow away from free-air catalogue values if it is not checked.
DKHR450-4KW.138.5HA aids refrigeration and condenser installation by using its centrifugal fan format to move air across refrigeration coils. Engineers should confirm mounting, thermal management flow direction and unit resistance to preserve the intended application value.
OEM designs for thermal load exchangers use DKHR450-4KW.138.5HA where a centrifugal fan must move air across transfer surfaces. This gives application makers a production-ready thermal load removal element that contributes to application reliability without changing the stated industry direction.
For equipment in heat-pump systems, Rosenberg DKHR450-4KW.138.5HA acts as a thermal management assembly that moves air through exchange sections. A confirmed operating point provides a stronger purchasing basis than selecting from maximum air delivery alone.
The matched source highlights 590 Pa maximum pressure stated for this model. Compare that point together with the listed electrical and dimensional data.
The supplied row lists 590 Pa pressure, 910 W input, 1300 rpm. Compare these values with the real system operating point, not only the free-air rating.
Compare the full model suffix, voltage, size, motor or controller type, mounting, airflow, pressure, power, speed, and protection; do not copy data from a similar model.
Available performance data includes 590 Pa pressure, 910 W input, 1300 rpm. Obtain the full curve when system resistance or part-load behavior matters.
Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.
The product is classified as a centrifugal fan. Use the full model code because nearby variants can differ in motor, mounting, and controls.

DKHR450-4SW.138.5HA is a 400 VAC centrifugal fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is a 450 mm size specified in the upload data. It also lists 6429 m³/h maximum airflow stated for this model. Review performance curve for cooling validation.
Read More
DKHR400-4KW.123.5FA is a 400 VAC centrifugal fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 1340 rpm rated speed in the supplied parameter row. It also lists a 400 mm size specified in the upload data. Review power budget for commissioning review.
Read More
DKHR560-4KW.132.6LA is a 400 VAC centrifugal fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 1350 rpm rated speed in the supplied parameter row. It also lists a 560 mm size specified in the upload data. Review system resistance for commissioning review.
Read More
DKHR400-4SW.123.5FA is a 400 VAC centrifugal fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 1340 rpm rated speed in the supplied parameter row. It also lists a 400 mm size specified in the upload data. Review operating point for ductwork design.
Read More
DKHR500-4SW.155.6LA is a 400 VAC centrifugal fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 500 mm size specified in the upload data. Review airflow path for cabinet planning.
Read More
DKHR500-4SW.155.6HF is a 400 VAC centrifugal fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 500 mm size specified in the upload data. Review mounting envelope for air-system design.
Read More