DKHR560-4SW.155.6LA is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 560 mm size specified in the upload data. Review installation clearance for air-system design.
| Rated Voltage(V) | 400 |
|---|---|
| Size(mm) | 560 |
| Input Power(W) | 2130 |
| Speed(rpm) | 1368 |
Installation makers serving air-handling, HVAC and refrigeration installation can integrate Rosenberg DKHR560-4SW.155.6LA as an AC axial fan for directed ventilation and component-level heat removal.
Axial air movement is appropriate where volume flow is the primary requirement and the completed installation does not impose excessive resistance.
Assembled approval should consider mounting, connector or lead arrangement, air delivery direction and access for future service.
The listed 400 V supply and 2130 W input give electrical designers a defined basis for power and interface planning. Confirm the exact operating point before production release. Preserve the specified air delivery direction during assembly.
System serving HVAC and ventilation systems can integrate Rosenberg DKHR560-4SW.155.6LA; the unit provides supply or exhaust moving air. Effective ventilation reinforces process continuity by keeping electronics and power devices within their intended temperature range.
As part of refrigeration and condenser hardware, Rosenberg DKHR560-4SW.155.6LA performs a defined heat removal task and moves air across refrigeration coils. Predictable air movement helps maintain component temperature as electrical load and ambient conditions change.
The Rosenberg AC axial fan DKHR560-4SW.155.6LA addresses thermal demand in heat exchangers by helping to moves air across transfer surfaces. Stable circulation helps reduce temperature gradients across boards, power sections and mechanical assemblies.
As part of heat-pump systems, Rosenberg DKHR560-4SW.155.6LA performs a defined forced-air cooling task and moves air through exchange sections. Designers should verify mounting, moving air direction and application resistance to preserve the intended application value.
The supplied application data covers data-communications equipment, heat pumps, ventilation systems. Confirm the installation's airflow, pressure, space, and electrical requirements.
Match the complete model code, voltage, dimensions, mounting arrangement, airflow direction, performance point, and control interface to the equipment.
The upload row lists RoHS compliance, but no additional exact-model certification is confirmed in the supplied feature record.
No exact IP protection level is stated for this item in the supplied sources. Confirm it before use in dusty, wet, or harsh locations.
Check supply voltage, controller signals, blocked airflow, contamination, abnormal noise, rotation, and the equipment operating point before replacing the unit.
No model-specific maintenance interval is supplied. Keep the airflow path clean, inspect mounting and electrical connections, and follow the exact product instructions.

DKHR500-4SW.155.6LA is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 1750 W input power for the listed electrical version. It also lists a 500 mm size specified in the upload data. Review pressure requirement for application engineering.
Read More
DKHR630-6SW.195.6LA is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is a 630 mm size specified in the upload data. It also lists 1400 W input power for the listed electrical version. Review power budget for air-system design.
Read More
DKHR560-4KW.132.6LA is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 560 mm size specified in the upload data. Review system resistance for energy review.
Read More
DKHR400-4SW.123.5FA is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 540 W input power for the listed electrical version. It also lists a 400 mm size specified in the upload data. Review equipment interface for final model confirmation.
Read More
DKHR500-4SW.155.6HF is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 1750 W input power for the listed electrical version. It also lists a 500 mm size specified in the upload data. Review installation clearance for cabinet planning.
Read More
DKHR710-6SW.219.7NA is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 600 Pa maximum pressure stated for this model. It also lists a 710 mm size specified in the upload data. Review wiring plan for air-system design.
Read More