Sanyo Denki 109E5724C510 combines a 172 × 150 × 51 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 172 × 150 × 51 mm format is the primary stated selection detail. Selection focus: selection criteria review supply requirement.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 172*150*51 |
SANYO DENKI positions 109E5724C510 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
Engineers should review the model-specific fan curve against filters, grilles and enclosure resistance to confirm the required operating point. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Measure installed sound in the final cabinet. This step reduces uncertainty during equipment qualification. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
109E5724C510 is suitable for server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
The San Ace 109E5724C510 supports thermal management in storage arrays and data appliances. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
For network and other ICT hardware, 109E5724C510 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
Input power is not stated in the supplied row and requires confirmation.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
No pressure value is supplied; request the performance curve if static pressure is important.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

EFB1524VHG offers a 4000 rpm axial fan option for 24VDC industrial cooling. Compared with the listed SHG entry, its 23.28 W input and 507.6 m3/h maximum airflow define a different operating point for equipment selection.
Read More
The EE80251B3-000U-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC blower option for telecom cabinets, base stations, and network equipment. Its 2600 rpm rating defines a lower-speed operating point. Base mounting verification on the stated acoustic value. Validate mounting and wiring from the model drawing.
Read More
The EEC0251B2-000U-G99 is SUNON's 12 VDC, 120 × 120 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 2700 rpm rating defines a lower-speed operating point. For airflow-path design, start with the supplied volume-flow figure. Obtain the applicable curve before final duty-point approval.
Read More
ER56C-4DN.F7.1R 130571/0Z41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, packaging machinery. Its main supplied feature is energy-efficient aerodynamic design highlighted in the supplied series data. It also lists a 560 mm size specified in the upload data. Review operating point for final model confirmation.
Read More
For industrial equipment, EFB1324SHE uses a 127 x 127 x 38 mm axial package rather than the common 120 mm format. The 24VDC fan lists 4600 rpm operation and 339.8 m3/h maximum airflow with 18 W input.
Read More
SUNON EF80151B1-Q01C-S99 combines a 80 × 80 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. 3.83 W input is the defining electrical load in the supplied data. The recorded speed benchmark should guide mounting verification. Validate mounting and wiring from the model drawing.
Read More