Within servers, UPS systems, and telecom equipment, 109R0624H4D01 provides a 60 × 60 × 25 mm, 24 VDC DC axial fan configuration. Series focus: high airflow and pressure. A listed input of 1.44 W is the notable efficiency-related parameter. Check compatibility risk checking static-pressure entry. Focus: compatibility risk checking.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 31.4 |
| Max.Pressure(Pa) | 40.2 |
| Input Power(W) | 1.44 |
| Speed(rpm) | 3800 |
| Noise(db) | 28 |
For servers, storage systems and ICT equipment, the SANYO DENKI 109R0624H4D01 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
The rated peak airflow of 31.4 m3/h combines with 40.2 Pa pressure capability to support useful flow after installation losses are considered. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Qualify performance with the production guard. This keeps sourcing decisions tied to validated system needs. Confirm the final fan curve in the assembled equipment.
For server chassis and computing nodes, 109R0624H4D01 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling.
SANYO DENKI 109R0624H4D01 serves storage arrays and data appliances that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling.
109R0624H4D01 is suitable for network and other ICT hardware. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
Its 24 VDC rating and documented a listed input of 1.44 w is the notable efficiency-related parameter. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 28 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.
Use rated voltage, 60 × 60 × 25 mm dimensions, 31.4 m³/h airflow, 3800 rpm, and 1.44 W input for preliminary comparison.

Suited to New Energy, ebm-papst R3G400-FJ75-01 is a 380-480V EC backward-curved centrifugal fan, with a listed pressure capability of 800 Pa. The rating aids system-fit checks. Its documented data supports integration planning.
Read More
Intended for New Energy, the ebm-papst R3G560-FA28-03 is a 380-480V EC backward-curved centrifugal fan, centered on a listed airflow of 18,535 m³/h. This helps guide installation planning.
Read More
Selected for New Energy, the ebm-papst R3G500-FA28-03 is a 380-480V EC backward-curved centrifugal fan, distinguished by a listed pressure capability of 794 Pa. It provides a practical sizing reference.
Read More
In Cleanroom equipment, R3G280-8317084540 is an EC backward-curved centrifugal fan whose documented profile includes 280 mm dimensions for installation planning; the supplied table leaves the rated voltage unspecified.
Read More
The R3G310-8317083844 serves Cleanroom as an EC backward-curved centrifugal fan, with 310 mm dimensions for installation planning as its clearest supplied attribute. No rated voltage is listed in the provided table.
Read More
For Cleanroom, R3G400-8317084403 provides an EC backward-curved centrifugal fan format with 400 mm dimensions for installation planning. Rated voltage is not shown in the supplied table and must be checked before selection.
Read More