Home > Products > By type > Axial Fans > 9A0612S402 | Sanyo Denki 12VDC 2.04W DC Axial Fan for UPS, server and telecom equipment cooling

9A0612S402 Sanyo Axial Fan

Brand :
Sanyo
Model:
9A0612S402 | Sanyo Denki 12VDC 2.04W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The 12 VDC Sanyo Denki 9A0612S402 is a DC axial fan sized 60 × 60 × 25 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. A listed input of 2.04 W is the notable efficiency-related parameter. Check airflow path balancing operating point. Focus: airflow path balancing.

Product Features

Rated Voltage(V)12
Size(mm)60*60*25
Max.Air Flow(m³/h)38.6
Max.Pressure(Pa)56.8
Input Power(W)2.04
Speed(rpm)4600
Noise(db)33

Product Features

Stable San Ace Fan

9A0612S402 is intended for dependable forced-air cooling in servers, storage systems and ICT equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.

Its 38.6 m3/h maximum airflow supports rapid air exchange, while 56.8 Pa pressure capability helps overcome resistance within the finished equipment. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Measure installed sound in the final cabinet. It gives integrators a practical acceptance criterion. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

Application Industry

Frequently Asked Questions

What should procurement confirm for 9A0612S402?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

How should 9A0612S402 be matched to an enclosure?

Check its 60 × 60 × 25 mm size, 38.6 m³/h airflow, 56.8 Pa pressure, mounting points, airflow direction, and system resistance.

What equipment is 9A0612S402 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

Can 9A0612S402 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What airflow is listed for 9A0612S402?

The worksheet lists 38.6 m³/h. Compare the operating point with system resistance and the official performance curve.

What is the lead time for 9A0612S402?

Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.