Within servers, UPS systems, and telecom equipment, 9A0624S402 provides a 60 × 60 × 25 mm, 24 VDC DC axial fan configuration. The supplied reference emphasizes high static pressure and high airflow. A listed input of 1.92 W is the notable efficiency-related parameter. Check wiring scheme review sound level. Focus: wiring scheme review sound level.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 38.6 |
| Max.Pressure(Pa) | 56.8 |
| Input Power(W) | 1.92 |
| Speed(rpm) | 4600 |
| Noise(db) | 33 |
The SANYO DENKI 9A0624S402 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
Its 38.6 m3/h maximum airflow supports rapid air exchange, while 56.8 Pa pressure capability helps overcome resistance within the finished equipment. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Allow service access for fan replacement. This keeps sourcing decisions tied to validated system needs. Confirm the final fan curve in the assembled equipment.
SANYO DENKI 9A0624S402 serves server chassis and computing nodes that operate with sustained internal heat. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
9A0624S402 is suitable for storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9A0624S402 supports thermal management in network and other ICT hardware. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service.
The worksheet lists 56.8 Pa. Use the official curve to match it to system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Its 24 VDC rating and documented a listed input of 1.92 w is the notable efficiency-related parameter. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 1.92 W. Check supply capacity and operating conditions before commissioning.

SUNON A2179-HBT TC.GN is a 230 VAC AC axial fan in a 176 × 176 × 89 mm format for commercial refrigeration and refrigerator cooling. Up to 569.5 m³/h is its most prominent listed performance figure. Use the documented sound level when planning airflow-path design. Obtain the applicable curve before final duty-point approval.
Read More
Prepared for HVAC Ventilation, ebm-papst A2E250-AE65-55 is a 230 V AC axial fan, presenting a listed airflow of 1,805 m³/h. This assists electrical and mechanical review. Its documented data supports integration planning.
Read More
Selected for HVAC Systems, ebm-papst A3G630-AR85-90 is a 380-480V EC axial fan, marked by 630 mm dimensions for installation planning. It provides a practical sizing reference. Its documented data supports integration planning.
Read More
Aimed at HVAC Ventilation, ebm-papst A2D250-AA26-72 is a 400 V AC axial fan, whose supplied data highlights a documented speed of 2,800 rpm. The rating aids system-fit checks. Its documented data supports integration planning.
Read More
Used in HVAC Ventilation, ebm-papst A2D300-AP02-02 is a 400 V AC axial fan, defined by a listed airflow of 3,350 m³/h. The data helps compare W-series variants. Its documented data supports integration planning.
Read More
Applied in HVAC Ventilation, ebm-papst A2D300-AD02-02 is a 400 V AC axial fan, whose key figure is a listed airflow of 2,825 m³/h. It gives buyers a documented reference. Its documented data supports integration planning.
Read More