Description:

9A0824S402 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 80 × 80 × 25 mm. Series focus: high airflow and pressure. 48.1 Pa maximum pressure is the most distinctive duty-point parameter. Check procurement data comparison airflow profile. Focus: procurement data comparison airflow profile.

Product Features

Rated Voltage(V)24
Size(mm)80*80*25
Max.Air Flow(m³/h)71.4
Max.Pressure(Pa)48.1
Input Power(W)2.4
Speed(rpm)3400
Noise(db)34

Product Features

Low Vibration Fan

The SANYO DENKI 9A0824S402 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.

The rated peak airflow of 71.4 m3/h combines with 48.1 Pa pressure capability to support useful flow after installation losses are considered. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.

Keep the impeller path clear of wiring. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment.

Application Industry

Frequently Asked Questions

Which application details matter most for 9A0824S402?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What maintenance does 9A0824S402 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Can 9A0824S402 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

How noisy is 9A0824S402?

The worksheet lists 34 dB. Enclosure acoustics, system resistance, and distance can change the installed result.

Can 9A0824S402 run continuously in a 24/7 system?

Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.