A 120 × 120 × 38 mm frame and 12 VDC rating define 9G1212E101, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 200.6 m³/h is the standout performance value. Check wiring scheme review airflow profile. Focus: wiring scheme review airflow profile.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 200.6 |
| Input Power(W) | 7.32 |
| Speed(rpm) | 3100 |
| Noise(db) | 46 |
The San Ace 9G1212E101 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.
The specified maximum airflow of 200.6 m3/h provides a measurable basis for estimating air exchange and selecting the required cooling margin. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Review grille loss at the required duty point. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9G1212E101 is suitable for server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
The San Ace 9G1212E101 supports thermal management in storage arrays and data appliances. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
For network and other ICT hardware, 9G1212E101 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
The worksheet lists 200.6 m³/h. Compare the operating point with system resistance and the official performance curve.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 12 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
The listed speed is 3100 rpm. Confirm control conditions and the actual duty point.

For water heating, G2E140-AG02-05 provides a 230 V AC centrifugal blower configuration. A key model-specific detail is a 140 mm frame with thermal-overload protection. It supports exact-model comparison for OEM sourcing.
Read More
G2E120-AR77-01 combines 230 V operation with a AC centrifugal blower format for ventilation systems. Among the supplied ratings, a 120 mm frame with thermal-overload protection clearly differentiates this variant.
Read More
Aimed at Boiler Systems, the ebm-papst G1G146-BA07-52 is a 24 V EC backward-curved centrifugal fan, for which the table lists a listed pressure capability of 500 Pa. This assists electrical and mechanical review.
Read More
Integrated into Boiler Systems, the ebm-papst G1G133-DE19-15 is a 24 V EC backward-curved centrifugal fan, specified with a documented 45 W input rating. The rating aids system-fit checks.
Read More
Suited to Boiler Systems, ebm-papst G1G097-AA05-01 is a 24 V EC backward-curved centrifugal fan, marked by a documented 16 W input rating. It provides a practical sizing reference.
Read More
In inverter cooling, G2D180-BD18-13 serves as a 400 V AC centrifugal blower. Its standout data point is 840 Pa pressure with IP00 protection. It supports exact-model comparison for OEM sourcing and replacement work.