Get Quote
Home > Products > By type > Axial Fans > 9G1212E1D01 | Sanyo Denki 12VDC 7.32W DC Axial Fan for UPS, server and telecom equipment cooling

9G1212E1D01 Sanyo Axial Fan

Brand :
Sanyo
Model:
9G1212E1D01 | Sanyo Denki 12VDC 7.32W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The 9G1212E1D01 is a Sanyo Denki 12 VDC, 119 × 119 × 38 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its system interface during mounting verification. Validate mounting and wiring from the model drawing. Focus: spares strategy planning electrical load.

Product Features

Rated Voltage(V)12
Size(mm)119*119*38
Max.Air Flow(m³/h)198
Max.Pressure(Pa)100
Input Power(W)7.32
Speed(rpm)3100
Noise(db)46

Product Features

Stable San Ace Fan

For servers, storage systems and ICT equipment, the SANYO DENKI 9G1212E1D01 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

With up to 198 m3/h airflow and 100 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Check exhaust separation from the intake zone. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

Application Industry

Frequently Asked Questions

What is the lead time for 9G1212E1D01?

Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.

What input power is listed for 9G1212E1D01?

The worksheet lists 7.32 W. Check supply capacity and operating conditions before commissioning.

What should be checked if 9G1212E1D01 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

Is 9G1212E1D01 easy to install and maintain?

Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.

How should 9G1212E1D01 be matched to an enclosure?

Check its 119 × 119 × 38 mm size, 198 m³/h airflow, 100 Pa pressure, mounting points, airflow direction, and system resistance.

Is 9G1212E1D01 suitable for high-reliability cooling?

Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.