9G1212G1D01 Sanyo Axial Fan

Brand :
Sanyo
Model:
9G1212G1D01 | Sanyo Denki 24VDC 5.04W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

Sanyo Denki configures 9G1212G1D01 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 25 mm dimensions. Its listed airflow of 170 m³/h is the standout performance value. Review its rotational rating during system-resistance review. Use the latest specification for frequency and tolerance limits.

Product Features

Rated Voltage(V)24
Size(mm)120*120*25
Max.Air Flow(m³/h)170
Max.Pressure(Pa)77
Input Power(W)5.04
Speed(rpm)3150
Noise(db)44

Product Features

Low Vibration Fan

The San Ace 9G1212G1D01 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.

The rated peak airflow of 170 m3/h combines with 77 Pa pressure capability to support useful flow after installation losses are considered. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Allow service access for fan replacement. The process documents the required installation conditions. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

Application Industry

Frequently Asked Questions

Which application details matter most for 9G1212G1D01?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What airflow is listed for 9G1212G1D01?

The worksheet lists 170 m³/h. Compare the operating point with system resistance and the official performance curve.

What is the lead time for 9G1212G1D01?

Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.

What supply voltage does 9G1212G1D01 require?

The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.

What should be checked if 9G1212G1D01 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.