9G1212H401 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 149.6 m³/h maximum airflow stated for this model. It also lists a 120*120*25 mm size specified in the upload data. Review performance curve for energy review. Check the exact variant before ordering.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 120*120*25 |
| Max.Air Flow(m³/h) | 149.6 |
| Max.Pressure(Pa) | 210 |
| Input Power(W) | 3.72 |
| Speed(rpm) | 2850 |
| Noise(db) | 40 |
SANYO DENKI 9G1212H401 is a DC axial fan selected for data centers and communication installation, where controlled temperature management flow protects operating margin in space-conscious or continuously loaded installation.
Axial air movement is appropriate where volume flow is the primary requirement and the completed installation does not impose excessive resistance.
OEM qualification should connect the fan choice to enclosure resistance, acoustic limits and the expected operating environment.
The listed 12 V supply and 3.72 W input give electrical designers a defined basis for power and interface planning. Confirm the exact operating point before production release. Preserve the specified temperature management flow direction during assembly.
The application of 9G1212H401 covers servers and data-communication hardware; here, the DC axial fan cools computing and network assemblies. Predictable air movement helps maintain component temperature as electrical load and ambient conditions change.
When assembled in power supplies, inverters and control cabinets, 9G1212H401 cools power modules and controls within the available installation space. Installation resistance can shift delivered thermal management flow away from free-air catalogue values if it is not checked.
When integrated in industrial automation application, 9G1212H401 ventilates drives and production electronics within the available application space. Reviewing the exact electrical interface and environmental limits enables a safer production release.
As part of medical and laboratory instruments, SANYO DENKI 9G1212H401 performs a defined temperature management task and cools enclosed instrument electronics. A controlled inlet and discharge path is important because recirculation can reduce usable temperature management capacity.
Verify the listed size, mounting pattern, fan housing or nozzle arrangement, airflow direction, and service clearance against the equipment drawing.
Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.
No guaranteed lead time is provided in the supplied sources. Confirm current stock, required quantity, production schedule, and shipping date with the supplier.
The supplied row lists 149.6 m³/h airflow, 210 Pa pressure, 3.72 W input, 2850 rpm, 40 dB. Compare these values with the real system operating point, not only the free-air rating.
The supplied files do not establish a universal 24/7 duty rating. Validate ambient conditions, duty cycle, protection, and maintenance requirements for continuous use.
The supplied application data covers servers, data-communications equipment, control cabinets. Confirm the installation's airflow, pressure, space, and electrical requirements.