A 119 × 119 × 25 mm frame and 24 VDC rating define 9G1224E4D01, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 193.2 m³/h is the standout performance value. Check selection criteria review duty-point values. Focus: selection criteria review duty-point values.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 119*119*25 |
| Max.Air Flow(m³/h) | 193.2 |
| Max.Pressure(Pa) | 98.1 |
| Input Power(W) | 8.88 |
| Speed(rpm) | 3650 |
| Noise(db) | 48 |
The SANYO DENKI 9G1224E4D01 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
A listed maximum airflow of 193.2 m3/h and maximum pressure of 98.1 Pa give engineers a clear basis for matching the fan to enclosure resistance. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.
Include filter loading in the airflow margin. The outcome supports dependable long-term equipment service. Confirm the final fan curve in the assembled equipment.
9G1224E4D01 is suitable for server chassis and computing nodes. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
The San Ace 9G1224E4D01 supports thermal management in storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
For network and other ICT hardware, 9G1224E4D01 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
Use rated voltage, 119 × 119 × 25 mm dimensions, 193.2 m³/h airflow, 3650 rpm, and 8.88 W input for preliminary comparison.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

Targeting dehumidifiers, G2E140-AL40-01 pairs 230 V operation with a AC centrifugal blower layout. For selection, its most distinctive listed attribute is IP44 protection with thermal-overload protection.
Read More
For water heating, G2E140-AG02-05 provides a 230 V AC centrifugal blower configuration. A key model-specific detail is a 140 mm frame with thermal-overload protection. It supports exact-model comparison for OEM sourcing.
Read More
G2E120-AR77-01 combines 230 V operation with a AC centrifugal blower format for ventilation systems. Among the supplied ratings, a 120 mm frame with thermal-overload protection clearly differentiates this variant.
Read More
Aimed at Boiler Systems, the ebm-papst G1G146-BA07-52 is a 24 V EC backward-curved centrifugal fan, for which the table lists a listed pressure capability of 500 Pa. This assists electrical and mechanical review.
Read More
Integrated into Boiler Systems, the ebm-papst G1G133-DE19-15 is a 24 V EC backward-curved centrifugal fan, specified with a documented 45 W input rating. The rating aids system-fit checks.
Read More
Suited to Boiler Systems, ebm-papst G1G097-AA05-01 is a 24 V EC backward-curved centrifugal fan, marked by a documented 16 W input rating. It provides a practical sizing reference.
Read More