For servers, UPS systems, and telecom equipment, 9GA0312P3K001 combines 12 VDC operation with a 38 × 38 × 28 mm DC axial fan design. Long-life series construction is the main characteristic stated in the supplied reference. 25000 rpm is the model's most prominent operating value. Selection focus: control interface planning electrical load.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 38*38*28 |
| Max.Air Flow(m³/h) | 36 |
| Max.Pressure(Pa) | 800 |
| Input Power(W) | 7.4 |
| Speed(rpm) | 25000 |
| Noise(db) | 59 |
9GA0312P3K001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
With up to 36 m3/h airflow and 800 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.
Check exhaust separation from the intake zone. This provides buyers with a traceable selection basis. Confirm the final fan curve in the assembled equipment.
The San Ace 9GA0312P3K001 supports thermal management in server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
For storage arrays and data appliances, 9GA0312P3K001 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
SANYO DENKI 9GA0312P3K001 serves network and other ICT hardware that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
Check its 38 × 38 × 28 mm size, 36 m³/h airflow, 800 Pa pressure, mounting points, airflow direction, and system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.
Its 12 VDC rating and documented 25000 rpm is the model's most prominent operating value. provide model-specific selection data without relying on unlisted claims.