Sanyo Denki configures 9GA0412G7002 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 40 × 40 × 15 mm dimensions. The 21.6 m³/h airflow figure supports its stated equipment-cooling role. During equipment integration, compare the model's motor input. Review connector, alarm, and sensor options separately.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*15 |
| Max.Air Flow(m³/h) | 21.6 |
| Max.Pressure(Pa) | 192 |
| Input Power(W) | 2.04 |
| Speed(rpm) | 13100 |
| Noise(db) | 42 |
9GA0412G7002 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
With up to 21.6 m3/h airflow and 192 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Check startup demand against the power supply. This provides buyers with a traceable selection basis. Confirm the final fan curve in the assembled equipment.
The San Ace 9GA0412G7002 supports thermal management in server chassis and computing nodes. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
For storage arrays and data appliances, 9GA0412G7002 provides a dedicated forced-air cooling path. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
SANYO DENKI 9GA0412G7002 serves network and other ICT hardware that operate with sustained internal heat. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.
Its 12 VDC rating and documented the 21.6 m³/h airflow figure supports its stated equipment-cooling role. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 42 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.