The 12 VDC Sanyo Denki 9GA0412H7001 is a DC axial fan sized 40 × 40 × 15 mm for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 0.72 W is the notable efficiency-related parameter. Selection focus: cooling margin validation duty-point values.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*15 |
| Max.Air Flow(m³/h) | 12.07 |
| Max.Pressure(Pa) | 59.8 |
| Input Power(W) | 0.72 |
| Speed(rpm) | 7300 |
| Noise(db) | 28 |
9GA0412H7001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
Its 12.07 m3/h maximum airflow supports rapid air exchange, while 59.8 Pa pressure capability helps overcome resistance within the finished equipment. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.
Keep the impeller path clear of wiring. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment.
SANYO DENKI 9GA0412H7001 serves server chassis and computing nodes that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling.
9GA0412H7001 is suitable for storage arrays and data appliances. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
The San Ace 9GA0412H7001 supports thermal management in network and other ICT hardware. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It supports reliable OEM equipment cooling.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 0.72 W. Check supply capacity and operating conditions before commissioning.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.