9GA0412P3G01 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Long-life series construction is the main characteristic stated in the supplied reference. 16500 rpm is the model's most prominent operating value. Selection focus: wiring scheme review volume-flow figure.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*28 |
| Max.Air Flow(m³/h) | 37 |
| Max.Pressure(Pa) | 450 |
| Input Power(W) | 4.68 |
| Speed(rpm) | 16500 |
| Noise(db) | 53 |
The SANYO DENKI 9GA0412P3G01 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
A listed maximum airflow of 37 m3/h and maximum pressure of 450 Pa give engineers a clear basis for matching the fan to enclosure resistance. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Verify the mating connector and lead reach. It supports stable operation across the intended load cycle. Confirm the final fan curve in the assembled equipment.
9GA0412P3G01 is suitable for server chassis and computing nodes. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9GA0412P3G01 supports thermal management in storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service.
For network and other ICT hardware, 9GA0412P3G01 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service.
The listed speed is 16500 rpm. Confirm control conditions and the actual duty point.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
Check its 40 × 40 × 28 mm size, 37 m³/h airflow, 450 Pa pressure, mounting points, airflow direction, and system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.