For thermal management in servers, UPS systems, and telecom equipment, the 9GA0412P3H01 provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 14500 rpm is the model's most prominent operating value. The recorded static-pressure entry should guide enclosure sizing. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*28 |
| Max.Air Flow(m³/h) | 32 |
| Max.Pressure(Pa) | 347 |
| Input Power(W) | 3.36 |
| Speed(rpm) | 14500 |
| Noise(db) | 50 |
9GA0412P3H01 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
With up to 32 m3/h airflow and 347 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Include filter loading in the airflow margin. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment.
The San Ace 9GA0412P3H01 supports thermal management in server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
For storage arrays and data appliances, 9GA0412P3H01 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
SANYO DENKI 9GA0412P3H01 serves network and other ICT hardware that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
The worksheet lists 12 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
The listed speed is 14500 rpm. Confirm control conditions and the actual duty point.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
The worksheet lists 347 Pa. Use the official curve to match it to system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.