9GA0412P3K01 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Long-life series construction is the main characteristic stated in the supplied reference. 22000 rpm is the model's most prominent operating value. Selection focus: power budget review installation footprint.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*28 |
| Max.Air Flow(m³/h) | 49 |
| Max.Pressure(Pa) | 799 |
| Input Power(W) | 11.04 |
| Speed(rpm) | 22000 |
| Noise(db) | 61 |
The San Ace 9GA0412P3K01 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.
A listed maximum airflow of 49 m3/h and maximum pressure of 799 Pa give engineers a clear basis for matching the fan to enclosure resistance. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Allow service access for fan replacement. This gives purchasing a controlled replacement reference. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9GA0412P3K01 is suitable for server chassis and computing nodes. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9GA0412P3K01 supports thermal management in storage arrays and data appliances. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
For network and other ICT hardware, 9GA0412P3K01 provides a dedicated forced-air cooling path. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.
The worksheet lists 49 m³/h. Compare the operating point with system resistance and the official performance curve.
Its 12 VDC rating and documented 22000 rpm is the model's most prominent operating value. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 61 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.