A 40 × 40 × 28 mm frame and 12 VDC rating define 9GA0412P3M01, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 12500 rpm is the model's most prominent operating value. Check enclosure space planning static-pressure entry.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*28 |
| Max.Air Flow(m³/h) | 27.6 |
| Max.Pressure(Pa) | 258 |
| Input Power(W) | 2.52 |
| Speed(rpm) | 12500 |
| Noise(db) | 47 |
The SANYO DENKI 9GA0412P3M01 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
With up to 27.6 m3/h airflow and 258 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Review airflow direction before design release. The outcome supports dependable long-term equipment service. Confirm the final fan curve in the assembled equipment.
The San Ace 9GA0412P3M01 supports thermal management in server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
For storage arrays and data appliances, 9GA0412P3M01 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
SANYO DENKI 9GA0412P3M01 serves network and other ICT hardware that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 12 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
The listed speed is 12500 rpm. Confirm control conditions and the actual duty point.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
Check its 40 × 40 × 28 mm size, 27.6 m³/h airflow, 258 Pa pressure, mounting points, airflow direction, and system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.