Sanyo Denki 9GA0412P6G001 is a 12 VDC DC axial fan in a 40 × 40 × 20 mm format for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 16000 rpm is the model's most prominent operating value. Check replacement fit screening mounting size.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*20 |
| Max.Air Flow(m³/h) | 25 |
| Max.Pressure(Pa) | 318 |
| Input Power(W) | 2.76 |
| Speed(rpm) | 16000 |
| Noise(db) | 47 |
9GA0412P6G001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
A listed maximum airflow of 25 m3/h and maximum pressure of 318 Pa give engineers a clear basis for matching the fan to enclosure resistance. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Map airflow around the hottest components. It supports stable operation across the intended load cycle. Confirm the final fan curve in the assembled equipment.
9GA0412P6G001 is suitable for server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
The San Ace 9GA0412P6G001 supports thermal management in storage arrays and data appliances. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It provides a practical cooling path for OEM integration.
For network and other ICT hardware, 9GA0412P6G001 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It provides a practical cooling path for OEM integration.
The worksheet lists 2.76 W. Check supply capacity and operating conditions before commissioning.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.
Check its 40 × 40 × 20 mm size, 25 m³/h airflow, 318 Pa pressure, mounting points, airflow direction, and system resistance.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.