Sanyo Denki 9GA0412P7G001 combines a 40 × 40 × 15 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. The 22 m³/h airflow figure supports its stated equipment-cooling role. Focus: control interface planning.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*15 |
| Max.Air Flow(m³/h) | 22 |
| Max.Pressure(Pa) | 192 |
| Input Power(W) | 2.04 |
| Speed(rpm) | 13100 |
| Noise(db) | 42 |
The San Ace 9GA0412P7G001 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.
Its 22 m3/h maximum airflow supports rapid air exchange, while 192 Pa pressure capability helps overcome resistance within the finished equipment. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Test component temperatures at peak load. It gives integrators a practical acceptance criterion. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
SANYO DENKI 9GA0412P7G001 serves server chassis and computing nodes that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It supports reliable OEM equipment cooling.
9GA0412P7G001 is suitable for storage arrays and data appliances. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
The San Ace 9GA0412P7G001 supports thermal management in network and other ICT hardware. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling. Verified.
The worksheet lists 192 Pa. Use the official curve to match it to system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.
PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 12 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.