For thermal management in servers, UPS systems, and telecom equipment, the 9GA0424P3G001 provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 16500 rpm is the model's most prominent operating value. The recorded duty-point values should guide replacement evaluation. Match the exact part number before approving a substitute.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40*40*28 |
| Max.Air Flow(m³/h) | 37 |
| Max.Pressure(Pa) | 450 |
| Input Power(W) | 5.28 |
| Speed(rpm) | 16500 |
| Noise(db) | 53 |
9GA0424P3G001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
Its 37 m3/h maximum airflow supports rapid air exchange, while 450 Pa pressure capability helps overcome resistance within the finished equipment. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Review grille loss at the required duty point. This confirms cooling margin before volume production. Confirm the final fan curve in the assembled equipment.
SANYO DENKI 9GA0424P3G001 serves server chassis and computing nodes that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. This helps maintain dependable equipment operation.
9GA0424P3G001 is suitable for storage arrays and data appliances. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
The San Ace 9GA0424P3G001 supports thermal management in network and other ICT hardware. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
Check its 40 × 40 × 28 mm size, 37 m³/h airflow, 450 Pa pressure, mounting points, airflow direction, and system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.