For thermal management in servers, UPS systems, and telecom equipment, the 9GA0424P3M0011 provides a 24 VDC DC axial fan configuration measuring 40×40×28 mm. 12500 rpm is the model's most prominent operating value. Base procurement comparison on the stated motor input. Confirm control inputs against the complete ordering code.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40×40×28 |
| Max.Air Flow(m³/h) | 27.6 |
| Max.Pressure(Pa) | 258 |
| Input Power(W) | 2.64 |
| Speed(rpm) | 12500 |
| Noise(db) | 47 |
The SANYO DENKI 9GA0424P3M0011 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
The rated peak airflow of 27.6 m3/h combines with 258 Pa pressure capability to support useful flow after installation losses are considered. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.
Review grille loss at the required duty point. The process documents the required installation conditions. Confirm the final fan curve in the assembled equipment.
For server chassis and computing nodes, 9GA0424P3M0011 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
SANYO DENKI 9GA0424P3M0011 serves storage arrays and data appliances that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
9GA0424P3M0011 is suitable for network and other ICT hardware. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
Use rated voltage, 40×40×28 mm dimensions, 27.6 m³/h airflow, 12500 rpm, and 2.64 W input for preliminary comparison.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.