The 9GA0512P7G001 is a Sanyo Denki 12 VDC, 52 × 52 × 15 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Review its selection parameters during airflow-path design. Confirm environmental protection for the ordered version.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 52*52*15 |
| Max.Air Flow(m³/h) | 30 |
| Max.Pressure(Pa) | 91.5 |
| Input Power(W) | 1.56 |
| Speed(rpm) | 7800 |
| Noise(db) | 38 |
SANYO DENKI positions 9GA0512P7G001 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
The rated peak airflow of 30 m3/h combines with 91.5 Pa pressure capability to support useful flow after installation losses are considered. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Test component temperatures at peak load. It gives integrators a practical acceptance criterion. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
For server chassis and computing nodes, 9GA0512P7G001 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
SANYO DENKI 9GA0512P7G001 serves storage arrays and data appliances that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
9GA0512P7G001 is suitable for network and other ICT hardware. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
The worksheet lists 30 m³/h. Compare the operating point with system resistance and the official performance curve.
Its 12 VDC rating and documented a listed input of 1.56 w is the notable efficiency-related parameter. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 38 dB. Enclosure acoustics, system resistance, and distance can change the installed result.