For thermal management in servers, UPS systems, and telecom equipment, the 9GA0612M701 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 15 mm. A listed input of 0.96 W is the notable efficiency-related parameter. Review its performance curve during procurement comparison. Treat bearing and life data as suffix-specific.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60*60*15 |
| Max.Air Flow(m³/h) | 27.03 |
| Max.Pressure(Pa) | 35.4 |
| Input Power(W) | 0.96 |
| Speed(rpm) | 3900 |
| Noise(db) | 28 |
The San Ace 9GA0612M701 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.
A listed maximum airflow of 27.03 m3/h and maximum pressure of 35.4 Pa give engineers a clear basis for matching the fan to enclosure resistance. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Check startup demand against the power supply. It also creates a clearer thermal approval record. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9GA0612M701 is suitable for server chassis and computing nodes. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9GA0612M701 supports thermal management in storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service.
For network and other ICT hardware, 9GA0612M701 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service.
Check its 60 × 60 × 15 mm size, 27.03 m³/h airflow, 35.4 Pa pressure, mounting points, airflow direction, and system resistance.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Its 12 VDC rating and documented a listed input of 0.96 w is the notable efficiency-related parameter. provide model-specific selection data without relying on unlisted claims.