Sanyo Denki configures 9GA0612P6S001 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 20 mm dimensions. A listed input of 1.8 W is the notable efficiency-related parameter. For cooling-margin review, start with the supplied motor input. Review connector, alarm, and sensor options separately.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60*60*20 |
| Max.Air Flow(m³/h) | 42 |
| Max.Pressure(Pa) | 81 |
| Input Power(W) | 1.8 |
| Speed(rpm) | 5500 |
| Noise(db) | 36 |
9GA0612P6S001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
Its 42 m3/h maximum airflow supports rapid air exchange, while 81 Pa pressure capability helps overcome resistance within the finished equipment. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Test component temperatures at peak load. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment.
SANYO DENKI 9GA0612P6S001 serves server chassis and computing nodes that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
9GA0612P6S001 is suitable for storage arrays and data appliances. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. This helps maintain dependable equipment operation. Verified.
The San Ace 9GA0612P6S001 supports thermal management in network and other ICT hardware. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. This helps maintain dependable equipment operation.
The worksheet lists 42 m³/h. Compare the operating point with system resistance and the official performance curve.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 1.8 W. Check supply capacity and operating conditions before commissioning.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
The worksheet lists 81 Pa. Use the official curve to match it to system resistance.