Sanyo Denki configures 9GA0624P6G001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 60 × 60 × 20 mm dimensions. 6850 rpm is the model's most prominent operating value. Review its supply requirement during enclosure sizing. Check the full suffix before confirming connector details. Focus: spares strategy planning.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60*60*20 |
| Max.Air Flow(m³/h) | 52.87 |
| Max.Pressure(Pa) | 124.5 |
| Input Power(W) | 2.88 |
| Speed(rpm) | 6850 |
| Noise(db) | 43 |
The San Ace 9GA0624P6G001 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.
A listed maximum airflow of 52.87 m3/h and maximum pressure of 124.5 Pa give engineers a clear basis for matching the fan to enclosure resistance. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Keep the impeller path clear of wiring. The outcome supports dependable long-term equipment service. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9GA0624P6G001 is suitable for server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
The San Ace 9GA0624P6G001 supports thermal management in storage arrays and data appliances. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
For network and other ICT hardware, 9GA0624P6G001 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 2.88 W. Check supply capacity and operating conditions before commissioning.
The listed speed is 6850 rpm. Confirm control conditions and the actual duty point.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.