A 80 × 80 × 25 mm frame and 12 VDC rating define 9GA0812P4H001, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 2.64 W is the notable efficiency-related parameter. Focus: selection criteria review dimensional envelope.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80*80*25 |
| Max.Air Flow(m³/h) | 88 |
| Input Power(W) | 2.64 |
| Speed(rpm) | 5200 |
| Noise(db) | 37 |
For servers, storage systems and ICT equipment, the SANYO DENKI 9GA0812P4H001 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
The specified maximum airflow of 88 m3/h provides a measurable basis for estimating air exchange and selecting the required cooling margin. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Preserve outlet space to limit recirculation. The result supports repeatable OEM assembly. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
For server chassis and computing nodes, 9GA0812P4H001 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
SANYO DENKI 9GA0812P4H001 serves storage arrays and data appliances that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
9GA0812P4H001 is suitable for network and other ICT hardware. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.
No pressure value is supplied; request the performance curve if static pressure is important.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.