The 9GA0812P4J001 is a Sanyo Denki 12 VDC, 80 × 80 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. For mounting verification, start with the supplied volume-flow figure. Use the latest specification for frequency and tolerance limits.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80*80*25 |
| Max.Air Flow(m³/h) | 124 |
| Max.Pressure(Pa) | 177.6 |
| Input Power(W) | 7.2 |
| Speed(rpm) | 7400 |
| Noise(db) | 48 |
The SANYO DENKI 9GA0812P4J001 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
With up to 124 m3/h airflow and 177.6 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Review grille loss at the required duty point. It gives integrators a practical acceptance criterion. Confirm the final fan curve in the assembled equipment.
The San Ace 9GA0812P4J001 supports thermal management in server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
For storage arrays and data appliances, 9GA0812P4J001 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
SANYO DENKI 9GA0812P4J001 serves network and other ICT hardware that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 7.2 W. Check supply capacity and operating conditions before commissioning.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.
The worksheet lists 177.6 Pa. Use the official curve to match it to system resistance.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.