The 9GA0824H4002 is a Sanyo Denki 24 VDC, 80 × 80 × 25.2 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. During spares assessment, compare the model's pressure capability. Review connector, alarm, and sensor options separately.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*25.2 |
| Max.Air Flow(m³/h) | 86.4 |
| Max.Pressure(Pa) | 87.2 |
| Input Power(W) | 2.4 |
| Speed(rpm) | 5200 |
| Noise(db) | 37 |
For servers, storage systems and ICT equipment, the SANYO DENKI 9GA0824H4002 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
Its 86.4 m3/h maximum airflow supports rapid air exchange, while 87.2 Pa pressure capability helps overcome resistance within the finished equipment. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Review grille loss at the required duty point. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment.
SANYO DENKI 9GA0824H4002 serves server chassis and computing nodes that operate with sustained internal heat. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. This helps maintain dependable equipment operation.
9GA0824H4002 is suitable for storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
The San Ace 9GA0824H4002 supports thermal management in network and other ICT hardware. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. This helps maintain dependable equipment operation.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
The listed speed is 5200 rpm. Confirm control conditions and the actual duty point.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.