A 80×80×38 mm frame and 24 VDC rating define 9GA0824P1H61, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 380 Pa maximum pressure is the most distinctive duty-point parameter. Selection focus: service access planning supply requirement.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80×80×38 |
| Max.Air Flow(m³/h) | 135 |
| Max.Pressure(Pa) | 380 |
| Input Power(W) | 7.2 |
| Speed(rpm) | 8250 |
| Noise(db) | 55 |
For servers, storage systems and ICT equipment, the SANYO DENKI 9GA0824P1H61 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
The rated peak airflow of 135 m3/h combines with 380 Pa pressure capability to support useful flow after installation losses are considered. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Verify the mating connector and lead reach. This keeps sourcing decisions tied to validated system needs. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
For server chassis and computing nodes, 9GA0824P1H61 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
SANYO DENKI 9GA0824P1H61 serves storage arrays and data appliances that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
9GA0824P1H61 is suitable for network and other ICT hardware. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
Its 24 VDC rating and documented 380 pa maximum pressure is the most distinctive duty-point parameter. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 55 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
The worksheet lists 380 Pa. Use the official curve to match it to system resistance.