Sanyo Denki 9GA0824P4H001 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 2.4 W is the notable efficiency-related parameter. Focus: selection criteria review.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*25 |
| Max.Air Flow(m³/h) | 88 |
| Max.Pressure(Pa) | 87.7 |
| Input Power(W) | 2.4 |
| Speed(rpm) | 5200 |
| Noise(db) | 37 |
9GA0824P4H001 is intended for dependable forced-air cooling in servers, storage systems and ICT equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.
A listed maximum airflow of 88 m3/h and maximum pressure of 87.7 Pa give engineers a clear basis for matching the fan to enclosure resistance. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.
Test component temperatures at peak load. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9GA0824P4H001 is suitable for server chassis and computing nodes. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
The San Ace 9GA0824P4H001 supports thermal management in storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. This helps maintain dependable equipment operation.
For network and other ICT hardware, 9GA0824P4H001 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. This helps maintain dependable equipment operation.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 37 dB. Enclosure acoustics, system resistance, and distance can change the installed result.