The 24 VDC Sanyo Denki 9GA0824P4J0011 is a DC axial fan sized 80 × 80 × 25 mm for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 7400 rpm is the model's most prominent operating value. Check spares strategy planning acoustic value.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*25 mm |
| Max.Air Flow(m³/h) | 124.2 |
| Max.Pressure(Pa) | 177.6 |
| Input Power(W) | 6.72 |
| Speed(rpm) | 7400 |
| Noise(db) | 48 |
The SANYO DENKI 9GA0824P4J0011 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
The rated peak airflow of 124.2 m3/h combines with 177.6 Pa pressure capability to support useful flow after installation losses are considered. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Test component temperatures at peak load. The outcome supports dependable long-term equipment service. Confirm the final fan curve in the assembled equipment.
For server chassis and computing nodes, 9GA0824P4J0011 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
SANYO DENKI 9GA0824P4J0011 serves storage arrays and data appliances that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
9GA0824P4J0011 is suitable for network and other ICT hardware. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
Check its 80 × 80 × 25 mm size, 124.2 m³/h airflow, 177.6 Pa pressure, mounting points, airflow direction, and system resistance.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
The worksheet lists 124.2 m³/h. Compare the operating point with system resistance and the official performance curve.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.