For servers, UPS systems, and telecom equipment, 9GA0924G402 combines 24 VDC operation with a 92 × 92 × 25.2 mm DC axial fan design. Long-life series construction is the main characteristic stated in the supplied reference. A listed noise figure of 39 dB is the key differentiating parameter. Selection focus: cooling margin validation rated dataset.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*25.2 |
| Max.Air Flow(m³/h) | 114.6 |
| Max.Pressure(Pa) | 82.2 |
| Input Power(W) | 3.6 |
| Speed(rpm) | 4400 |
| Noise(db) | 39 |
The San Ace 9GA0924G402 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.
A listed maximum airflow of 114.6 m3/h and maximum pressure of 82.2 Pa give engineers a clear basis for matching the fan to enclosure resistance. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.
Verify mounting rigidity under continuous duty. It also creates a clearer thermal approval record. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9GA0924G402 is suitable for server chassis and computing nodes. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
The San Ace 9GA0924G402 supports thermal management in storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling.
For network and other ICT hardware, 9GA0924G402 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling.
The worksheet lists 39 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
Use rated voltage, 92 × 92 × 25.2 mm dimensions, 114.6 m³/h airflow, 4400 rpm, and 3.6 W input for preliminary comparison.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.