The 9GA0924H402 is a Sanyo Denki 24 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. For power-budget planning, start with the supplied frame geometry. Treat bearing and life data as suffix-specific.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*25 |
| Max.Air Flow(m³/h) | 87.04 |
| Input Power(W) | 2.16 |
| Speed(rpm) | 3300 |
| Noise(db) | 31 |
SANYO DENKI positions 9GA0924H402 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
The specified maximum airflow of 87.04 m3/h provides a measurable basis for estimating air exchange and selecting the required cooling margin. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Confirm the operating environment for the suffix. It supports a clear fan specification for future servicing. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9GA0924H402 is suitable for server chassis and computing nodes. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9GA0924H402 supports thermal management in storage arrays and data appliances. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
For network and other ICT hardware, 9GA0924H402 provides a dedicated forced-air cooling path. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. The application supports stable equipment service.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
No pressure value is supplied; request the performance curve if static pressure is important.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
The worksheet lists 87.04 m³/h. Compare the operating point with system resistance and the official performance curve.