The 92 × 92 × 25 mm Sanyo Denki 9GA0924P4G03 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Review its cooling specification during cabinet ventilation planning. Obtain the applicable curve before final duty-point approval.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*25 |
| Max.Air Flow(m³/h) | 116 |
| Max.Pressure(Pa) | 81 |
| Input Power(W) | 3.6 |
| Speed(rpm) | 4400 |
| Noise(db) | 39 |
SANYO DENKI positions 9GA0924P4G03 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
A listed maximum airflow of 116 m3/h and maximum pressure of 81 Pa give engineers a clear basis for matching the fan to enclosure resistance. The fan converts electrical input into focused air movement for efficient cooling. Its mechanical layout supports repeatable installation and dependable operation in OEM equipment. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Confirm the operating environment for the suffix. It also creates a clearer thermal approval record.
9GA0924P4G03 is suitable for server chassis and computing nodes. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
The San Ace 9GA0924P4G03 supports thermal management in storage arrays and data appliances. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It supports reliable OEM equipment cooling.
For network and other ICT hardware, 9GA0924P4G03 provides a dedicated forced-air cooling path. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It supports reliable OEM equipment cooling.
The worksheet lists 116 m³/h. Compare the operating point with system resistance and the official performance curve.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.