The 9GA0924P4J031 is a Sanyo Denki 24 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Base enclosure sizing on the stated rated dataset. Match the exact part number before approving a substitute. Focus: duty point matching.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*25 |
| Max.Air Flow(m³/h) | 132.09 |
| Max.Pressure(Pa) | 104.6 |
| Input Power(W) | 4.8 |
| Speed(rpm) | 5000 |
| Noise(db) | 43 |
9GA0924P4J031 is intended for dependable forced-air cooling in servers, storage systems and ICT equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.
A listed maximum airflow of 132.09 m3/h and maximum pressure of 104.6 Pa give engineers a clear basis for matching the fan to enclosure resistance. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Qualify performance with the production guard. It supports a clear fan specification for future servicing. Confirm the final fan curve in the assembled equipment.
9GA0924P4J031 is suitable for server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
The San Ace 9GA0924P4J031 supports thermal management in storage arrays and data appliances. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
For network and other ICT hardware, 9GA0924P4J031 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
The worksheet lists 104.6 Pa. Use the official curve to match it to system resistance.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
The worksheet lists 132.09 m³/h. Compare the operating point with system resistance and the official performance curve.