Configured for servers, UPS systems, and telecom equipment, Sanyo Denki 9GA1248P4G001 is a 48 VDC DC axial fan in a 120×120×25 mm frame. 365 Pa maximum pressure is the most distinctive duty-point parameter. Long-life series construction is the main characteristic stated in the supplied reference. Focus: compatibility risk checking.
| Rated Voltage(V) | 48 |
|---|---|
| Size(mm) | 120×120×25 |
| Max.Air Flow(m³/h) | 228 |
| Max.Pressure(Pa) | 365 |
| Input Power(W) | 11.52 |
| Speed(rpm) | 6400 |
| Noise(db) | 57 |
9GA1248P4G001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
With up to 228 m3/h airflow and 365 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Measure installed sound in the final cabinet. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment.
The San Ace 9GA1248P4G001 supports thermal management in server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It supports reliable OEM equipment cooling.
For storage arrays and data appliances, 9GA1248P4G001 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It supports reliable OEM equipment cooling.
SANYO DENKI 9GA1248P4G001 serves network and other ICT hardware that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It supports reliable OEM equipment cooling.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 57 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.
Check its 120×120×25 mm size, 228 m³/h airflow, 365 Pa pressure, mounting points, airflow direction, and system resistance.