9GL1224G101 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 119 × 119 × 38 mm. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 230.4 m³/h is the standout performance value. Check airflow path balancing supply requirement.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 119*119*38 |
| Max.Air Flow(m³/h) | 230.4 |
| Max.Pressure(Pa) | 135 |
| Input Power(W) | 12 |
| Speed(rpm) | 3600 |
| Noise(db) | 49 |
SANYO DENKI positions 9GL1224G101 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
Its 230.4 m3/h maximum airflow supports rapid air exchange, while 135 Pa pressure capability helps overcome resistance within the finished equipment. Its counter-rotating airflow architecture is intended for demanding pressure duty in space-constrained electronic systems. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Verify mounting rigidity under continuous duty. This keeps sourcing decisions tied to validated system needs.
SANYO DENKI 9GL1224G101 serves server chassis and computing nodes that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation.
9GL1224G101 is suitable for storage arrays and data appliances. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It provides a practical cooling path for OEM integration.
The San Ace 9GL1224G101 supports thermal management in network and other ICT hardware. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It provides a practical cooling path for OEM integration.
The worksheet lists 49 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
Check its 119 × 119 × 38 mm size, 230.4 m³/h airflow, 135 Pa pressure, mounting points, airflow direction, and system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.