The 48 VDC Sanyo Denki 9GL1248H1D01 is a DC axial fan sized 120 × 120 × 38 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its 2600 rpm rating defines a lower-speed operating point. Check thermal margin assessment installation footprint. Focus: thermal margin assessment installation footprint.
| Rated Voltage(V) | 48 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 166.2 |
| Max.Pressure(Pa) | 70.5 |
| Input Power(W) | 5.28 |
| Speed(rpm) | 2600 |
| Noise(db) | 39 |
The SANYO DENKI 9GL1248H1D01 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
The rated peak airflow of 166.2 m3/h combines with 70.5 Pa pressure capability to support useful flow after installation losses are considered. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Test component temperatures at peak load. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment.
For server chassis and computing nodes, 9GL1248H1D01 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation.
SANYO DENKI 9GL1248H1D01 serves storage arrays and data appliances that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation.
9GL1248H1D01 is suitable for network and other ICT hardware. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It provides a practical cooling path for OEM integration. Verified.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 48 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
The listed speed is 2600 rpm. Confirm control conditions and the actual duty point.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.