The 24 VDC Sanyo Denki 9GT1224P1S001 is a DC axial fan sized 120 × 120 × 38 mm for servers, UPS systems, and telecom equipment. The series cooling function is confirmed; suffix-specific options require datasheet verification. Its listed airflow of 360.06 m³/h is the standout performance value. Focus: control interface planning cooling output.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 360.06 |
| Max.Pressure(Pa) | 269 |
| Input Power(W) | 26.4 |
| Speed(rpm) | 5600 |
| Noise(db) | 58 |
9GT1224P1S001 is intended for dependable forced-air cooling in refrigeration controls and cooling equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.
The rated peak airflow of 360.06 m3/h combines with 269 Pa pressure capability to support useful flow after installation losses are considered. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Review airflow direction before design release. This provides buyers with a traceable selection basis. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.

GTW012FU804-U00 brings EC axial operation to a 120 x 120 x 38 mm server-cooling format. With 220VAC listed in the supplied table, the fan is specified at 4200 rpm and 246.5 m3/h maximum airflow.
Read More
GTM031PBM22R is an EC centrifugal fan for AHU and precision air-conditioning systems. The supplied fan-wall PDF specifies three-phase 380-480VAC operation and a maximum input of 1250 W for each fan.
Read More
GTW040FUC15E-M001 combines EC axial fan cooling with a nominal 230VAC supply for server and precision equipment. Its listed 5350 m3/h maximum airflow and 1650 rpm speed define this model's ventilation profile.
Read More
GTW063HBK21E-M001 is listed as an EC axial fan for server cooling on three-phase 230/400VAC. Its supplied 805 x 805 x 225 mm dimensions and 1200 rpm speed define the mechanical and operating selection points.
Read More
GTB031FUC20R N1 is a nominal 230VAC EC centrifugal fan for server cooling. RS485 control and voltage/current monitoring are documented in its PDF, alongside 3014 m3/h maximum airflow and a 2500 rpm speed.
Read More
GTB040PUD26R-M002 is a 400VAC EC centrifugal fan for server ventilation. Its supplied 404 mm diameter and 256.6 mm depth accompany a 1850 rpm speed, with 6004.4 m3/h maximum airflow listed.