Sanyo Denki 9HV0612P1J001 is a 12 VDC DC axial fan in a 60 × 60 × 38 mm format for AI servers and high-density electronics. Ultra-high static-pressure capability is the representative series characteristic. 1743.6 Pa maximum pressure is the most distinctive duty-point parameter. Check airflow path balancing catalog specification.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60*60*38 |
| Max.Air Flow(m³/h) | 112.88 |
| Max.Pressure(Pa) | 1743.6 |
| Input Power(W) | 32.4 |
| Speed(rpm) | 21700 |
| Noise(db) | 68 |
SANYO DENKI positions 9HV0612P1J001 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
Its 112.88 m3/h maximum airflow supports rapid air exchange, while 1743.6 Pa pressure capability helps overcome resistance within the finished equipment. The fan converts electrical input into focused air movement for efficient cooling. Its mechanical layout supports repeatable installation and dependable operation in OEM equipment. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Review grille loss at the required duty point. The result supports repeatable OEM assembly.
SANYO DENKI 9HV0612P1J001 serves server chassis and computing nodes that operate with sustained internal heat. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It provides a practical cooling path for OEM integration.
9HV0612P1J001 is suitable for storage arrays and data appliances. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
The San Ace 9HV0612P1J001 supports thermal management in network and other ICT hardware. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
The worksheet lists 12 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
Check its 60 × 60 × 38 mm size, 112.88 m³/h airflow, 1743.6 Pa pressure, mounting points, airflow direction, and system resistance.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.