Sanyo Denki configures 9HV0848P1G001 for servers and data-center equipment as a 48 VDC DC axial fan with 80 × 80 × 38 mm dimensions. The supplied row lists 69 dB as an important acoustic selection value. Base enclosure sizing on the stated pressure capability. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 48 |
|---|---|
| Size(mm) | 80*80*38 |
| Max.Air Flow(m³/h) | 222.02 |
| Max.Pressure(Pa) | 1000.6 |
| Input Power(W) | 40.8 |
| Speed(rpm) | 14900 |
| Noise(db) | 69 |
9HV0848P1G001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
With up to 222.02 m3/h airflow and 1000.6 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Review grille loss at the required duty point. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment.
The San Ace 9HV0848P1G001 supports thermal management in server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
For storage arrays and data appliances, 9HV0848P1G001 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
SANYO DENKI 9HV0848P1G001 serves network and other ICT hardware that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.
No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Its 48 VDC rating and documented the supplied row lists 69 db as an important acoustic selection value. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 40.8 W. Check supply capacity and operating conditions before commissioning.
The listed speed is 14900 rpm. Confirm control conditions and the actual duty point.