Within AI servers and high-density electronics, 9HV3612P3K001 provides a 36 × 36 × 28 mm, 12 VDC DC axial fan configuration. Ultra-high static-pressure capability is the representative series characteristic. 32500 rpm is the model's most prominent operating value. Check airflow path balancing sound level. Focus: airflow path balancing sound level.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 36*36*28 |
| Max.Air Flow(m³/h) | 43 |
| Max.Pressure(Pa) | 1400 |
| Input Power(W) | 21 |
| Speed(rpm) | 32500 |
| Noise(db) | 67 |
9HV3612P3K001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
A listed maximum airflow of 43 m3/h and maximum pressure of 1400 Pa give engineers a clear basis for matching the fan to enclosure resistance. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Confirm inlet clearance around nearby cables. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment.
9HV3612P3K001 is suitable for server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
The San Ace 9HV3612P3K001 supports thermal management in storage arrays and data appliances. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation.
For network and other ICT hardware, 9HV3612P3K001 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation.
The worksheet lists 21 W. Check supply capacity and operating conditions before commissioning.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.
Check its 36 × 36 × 28 mm size, 43 m³/h airflow, 1400 Pa pressure, mounting points, airflow direction, and system resistance.
It is listed for AI servers and high-density electronics. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.