Sanyo Denki configures 9HV5724P5H001 for AI servers and high-density electronics as a 24 VDC DC axial fan with 172 × 150 × 51 mm dimensions. The supplied row lists 77 dB as an important acoustic selection value. Use the documented rated dataset when planning replacement evaluation. Treat bearing and life data as suffix-specific.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 172*150*51 |
| Max.Air Flow(m³/h) | 737.8 |
| Max.Pressure(Pa) | 1001.3 |
| Input Power(W) | 120 |
| Speed(rpm) | 8000 |
| Noise(db) | 77 |
For servers, storage systems and ICT equipment, the SANYO DENKI 9HV5724P5H001 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
The rated peak airflow of 737.8 m3/h combines with 1001.3 Pa pressure capability to support useful flow after installation losses are considered. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Verify the mating connector and lead reach. It supports a clear fan specification for future servicing. Confirm the final fan curve in the assembled equipment.
For server chassis and computing nodes, 9HV5724P5H001 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation.
SANYO DENKI 9HV5724P5H001 serves storage arrays and data appliances that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation.
9HV5724P5H001 is suitable for network and other ICT hardware. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It provides a practical cooling path for OEM integration. Verified.
The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.